Cases and Tables¶
A Case holds editable pandas tables. Load a standard PYPOWER/MATPOWER case,
edit or add tables, then use to_pypower() for the standard electrical model
or to_excel()/load_excel() to retain the complete GridForge Case.
Loading a Case¶
load_case() accepts:
- a built-in PYPOWER case name;
- a local PYPOWER
.pycase; - a local MATPOWER
.mcase; - a PYPOWER dictionary, for example the result of
case14().
import gridforge as gf
case = gf.load_case("case14")
copied = case.copy() # Independent copy; load_case(case) is not supported.
from pypower.api import case14
case = gf.load_case(case14()) # A PYPOWER dictionary is accepted too.
For an end-to-end example using pandas edits and three custom device types, see the worked tutorial. For short signatures and return types, see the API reference.
Standard input boundary¶
load_case() reads only version, baseMVA, bus, gen, branch, and
optional gencost. Other top-level fields, including custom solar or
battery data, are ignored. Supported matrix layouts are listed at the end
of this page.
load_case() checks table structure, unique bus IDs, and the bus references in
gen and branch. dc_model() and ac_model() check the electrical
parameters they use; only dc_model() requires a connected online network.
Named Tables¶
case[name] returns a mutable pandas DataFrame. Standard tables are bus,
gen, branch, and optional gencost:
bus = case["bus"]
bus["PD"]
case["gen"]["PMAX"]
case["branch"]["F_BUS_IDX"]
GridForge gives these columns readable names such as BUS_IDX, PD,
PMAX, F_BUS_IDX, and STATUS.
Column order and meanings follow the MATPOWER case format,
but some GridForge names differ: BUS_IDX replaces BUS_I or GEN_BUS,
F_BUS_IDX replaces F_BUS, and STATUS replaces GEN_STATUS or BR_STATUS
in the corresponding tables.
BUS_IDX contains the real case bus identifier; it is not the DataFrame index
or row position. Non-contiguous and unsorted bus IDs are preserved.
Direct pandas edits are intentional:
case["bus"].loc[case["bus"]["BUS_IDX"] == 4, "PD"] = 60
branch = case["branch"]
line_1_2 = (branch["F_BUS_IDX"] == 1) & (branch["T_BUS_IDX"] == 2)
branch.loc[line_1_2, "STATUS"] = 0
Adding a Component Table¶
Create device rows with pandas, then register the completed DataFrame:
import pandas as pd
solar = pd.DataFrame({"BUS_IDX": [2, 6], "PMAX": [50.0, 80.0]})
case.add_component("solar", solar)
# Registration copies the DataFrame; edit the stored table thereafter.
case["solar"].loc[0, "PMAX"] = 60
add_component() registers a copy and returns None. Use pandas to create
or edit rows; registration does not update or replace an existing table.
BUS_IDX and device-specific parameters are not checked at registration.
Tables without BUS_IDX can still be stored and exported, but
connection_matrix() requires valid bus identifiers when building a map.
PYPOWER Export¶
case["gen"]["TECHNOLOGY"] = "thermal"
ppc = case.to_pypower()
# TECHNOLOGY remains in the Case but is omitted from ppc["gen"].
to_pypower() uses the current values and row order of the standard tables.
It exports their recorded PYPOWER columns in standard order, even if you
reorder the DataFrame columns. This includes PF/OPF result columns present
when loading. Added columns and custom component tables are omitted;
gencost is omitted if absent.
Python Case File Save and Load¶
Save the standard electrical model as an independent PYPOWER case:
case = gf.load_case("case14")
path = case.to_python("case_custom.py")
After saving to python file case_custom.py, you can load it using normal gridforge method.
restored = gf.load_case(path)
Similar to pypower style The filename stem becomes the function name. Existing files are protected unless
overwrite=True.
The generated file requires only NumPy and works with normal Python imports and PYPOWER's file loader:
# From case_custom.py file import the function callsed case_custom
from case_custom import case_custom
ppc = case_custom()
# Alternatively
from pypower.loadcase import loadcase
same_case = loadcase("case_custom.py")
Each function call returns a fresh dictionary and independent arrays.
Standard values, row order, bus IDs, empty matrix shapes and loaded PF/OPF
result columns are preserved. Float literals retain full float64 precision;
NaN and infinity are also preserved. Output follows gridforge's to_pypower(): added columns, custom tables and metadata are omitted, and absent gencost remains absent. Use Excel when those additional tables and metadata must be retained.
Excel Save and Load¶
Save all Case tables, including registered components and added columns, then
restore them with load_excel():
case.to_excel("scenario.xlsx")
restored = gf.load_excel("scenario.xlsx")
solar = restored["solar"]
Existing files are protected by default; use overwrite=True only when
replacement is intended.
The workbook has one sheet per table and a case_info sheet for the power
base, case version, metadata, and standard export schema. Table, row, and
column order and real BUS_IDX values are retained. load_excel() accepts GridForge workbooks, while
load_case() does not accept .xlsx files.
Supported Standard Input Layouts¶
load_case() accepts these complete version-2 matrix layouts. Input arrays
must retain the MATPOWER column order:
GridForge cannot detect swapped columns when the width is still supported.
| Table | Supported column counts | Meaning |
|---|---|---|
bus |
13, 17 | Standard input; OPF result columns |
gen |
21, 25 | Standard input; OPF result columns |
branch |
13, 17, 21 | Standard input; PF results; OPF results |
gencost |
Variable | Parameters declared by each row's MODEL and NCOST |
gencost, when present, has one active-power cost row per generator or twice
as many rows for active and reactive costs. MODEL=1 uses NCOST
power/cost pairs; MODEL=2 uses NCOST polynomial coefficients.
Common PYPOWER case:¶
| Name | Description |
|---|---|
| case4gs | 4-bus, 2-generator case from Grainger & Stevenson |
| case6ww | 6-bus, 3-generator case from Wood & Wollenberg |
| case9 | 9-bus, 3-generator case |
| case9Q | 9-bus case with reactive generation costs |
| case14 | IEEE 14-bus test case |
| case24_ieee_rts | IEEE Reliability Test System |
| case30 | 30-bus, 6-generator case |
| case30Q | 30-bus case with reactive generation costs |
| case30pwl | 30-bus case with piecewise linear generator costs |
| case39 | 39-bus New England system |
| case57 | IEEE 57-bus test case |
| case118 | IEEE 118-bus test case |
| case300 | IEEE 300-bus test case |
Availability follows the installed PYPOWER version. See the PYPOWER source for the complete list.